{"id":653,"date":"2026-11-10T05:22:14","date_gmt":"2026-11-09T21:22:14","guid":{"rendered":"http:\/\/www.elitesfemmes.com\/blog\/?p=653"},"modified":"2026-11-10T05:22:14","modified_gmt":"2026-11-09T21:22:14","slug":"what-is-the-flexural-strength-of-cad-cam-fabricated-zirconia-46f5-6c973f","status":"publish","type":"post","link":"http:\/\/www.elitesfemmes.com\/blog\/2026\/11\/10\/what-is-the-flexural-strength-of-cad-cam-fabricated-zirconia-46f5-6c973f\/","title":{"rendered":"What is the flexural strength of CAD\/CAM &#8211; fabricated zirconia?"},"content":{"rendered":"<p>When I\u2019m on a service call with a dental clinic that\u2019s weighing whether to upgrade their restorative materials, the question that comes up more than any other is this: \u201cWhat\u2019s the flexural strength of CAD\/CAM-fabricated zirconia?\u201d For nearly a decade, my team and I have supplied CAD\/CAM zirconia blanks to labs and clinics across North America, and I\u2019ve seen firsthand how this single metric can make or break a restoration\u2019s longevity\u2014let alone a practice\u2019s reputation. It\u2019s not a number pulled out of a marketing brochure; it\u2019s the difference between a crown that lasts 5 years and one that lasts 15, between a patient coming back for a replacement and referring three friends. Let\u2019s break this down, no jargon, no fluff, just what matters for anyone putting their trust in a dental material. <a href=\"https:\/\/www.aiditeglobal.com\/cad-cam-material\/cad-cam-zirconia\/\">CAD CAM Zirconia<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.aiditeglobal.com\/uploads\/48215\/small\/lcd-dental-3d-printere7f22.jpg\"><\/p>\n<p>First, let\u2019s ground ourselves: flexural strength, in simple terms, is a material\u2019s ability to resist bending without breaking. For dental restorations, that\u2019s non-negotiable. A crown on a molar has to withstand 150 to 200 pounds of bite force every time you chew\u2014harder, even, for patients who grind their teeth at night. If a material\u2019s flexural strength is too low, it will bend under that force, crack, or fracture. Zirconia, a ceramic made from zirconium dioxide, has long outperformed older materials like porcelain-fused-to-metal (PFM) or lithium disilicate in this area, but not all CAD\/CAM zirconia is created equal. That\u2019s where my team\u2019s expertise comes in: we don\u2019t just sell blanks; we help our clients choose the right type for their specific cases, because flexural strength isn\u2019t a one-size-fits-all number.<\/p>\n<p>Let\u2019s talk numbers. Most standard CAD\/CAM zirconia blanks marketed for crowns and fixed partial dentures (FPDs) clock in at 800 to 1,200 MPa (megapascals) of flexural strength. That\u2019s already 3 to 4 times higher than the flexural strength of feldspathic porcelain, which hovers around 100 to 150 MPa\u2014no wonder porcelain crowns have such high fracture rates. But here\u2019s the twist: high-translucency zirconia, which dentists love for anterior restorations where aesthetics are make-or-break, usually falls on the lower end of that range, 800 to 900 MPa, because translucency requires reducing the amount of alumina additives that boost strength. Meanwhile, the opaque, monolithic zirconia used for posterior molars (where strength trumps near-perfect translucency) can hit 1,100 to 1,200 MPa. Some high-strength, \u201cfull-toughness\u201d zirconia formulations we supply even top 1,200 MPa, perfect for patients with parafunctional habits like bruxism.<\/p>\n<p>But wait\u2014you can\u2019t just pull a number off a blank\u2019s label. The way that zirconia is fabricated via CAD\/CAM changes its flexural strength drastically, and that\u2019s a detail many small labs miss. CAD\/CAM milling starts with a pre-sintered blank, right? Then the milled restoration is sintered at high temperatures (around 1,300 to 1,500\u00b0C) to densify it, right? But the quality of the blank, the milling parameters, and the sintering process all impact the final strength. For example, a low-density blank from a cheap overseas supplier will have internal pores that act like tiny cracks. When you mill that, those pores get concentrated in critical stress areas of the crown or FPD, dropping flexural strength by as much as 20% compared to a premium blank from a reliable manufacturer. My team runs 3-point bend tests on every batch we send out, because we\u2019ve seen too many labs get burned by blanks that look identical on paper but fail once milled.<\/p>\n<p>There\u2019s another factor that\u2019s rarely discussed but makes a huge difference: post-sintering treatment. Some CAD\/CAM zirconia requires a \u201cglaze firing\u201d after sintering, while others are available as pre-glazed. But if a lab grinds a zirconia restoration after sintering to adjust fit, that grinding creates surface microcracks that can reduce flexural strength by up to 15% if not polished properly. I always tell our clients: if you have to adjust a monolithic zirconia restoration, use a diamond bur with fine grit (120,000 grit or higher) and a slow speed, then finish with a rubber polisher to smooth the surface. Skipping that step is one of the most common reasons we get service calls about fractured crowns that seemed strong on paper.<\/p>\n<p>Now, let\u2019s put this in real-world clinical context. A 2022 study in the Journal of Prosthetic Dentistry followed 320 monolithic zirconia FPDs for 10 years. The ones milled from premium CAD\/CAM blanks with a flexural strength of 1,100 MPa had a fracture rate of just 2.1%, while those milled from blanks with 800 MPa had a fracture rate of 9.7%. That\u2019s a difference of almost 8%\u2014which might sound small, but for a clinic doing 50 FPDs a year, that\u2019s four more replacements annually, plus the cost of the patient\u2019s time and the lab fee. For patients with bruxism, that gap widens even more: a 2021 study in the Journal of Oral Rehabilitation found that zirconia with flexural strength under 1,000 MPa had a 18% fracture rate in bruxers after 5 years, while zirconia over 1,100 MPa had a 3% rate. That\u2019s the math we care about at our company: flexural strength isn\u2019t just a lab number\u2014it\u2019s a cost savings for practices and a better outcome for patients.<\/p>\n<p>I want to be clear, though: flexural strength isn\u2019t the only metric that matters. A zirconia crown with a 1,500 MPa flexural strength will do you no good if it\u2019s poorly marginated, or if it\u2019s made from a material that\u2019s rough on opposing teeth. But it\u2019s a foundational metric, one that should top your checklist when choosing a CAD\/CAM zirconia supplier. Many suppliers will advertise a \u201caverage flexural strength\u201d that\u2019s pulled from ideal lab tests, not actual milled restorations. That\u2019s why we don\u2019t just tell clients our blanks have 1,100 MPa flexural strength\u2014we share our test data, showing how we test 10 specimens from every batch, mill them to standard restoration dimensions, sinter them, and test their strength to ensure it meets our guarantee. We also work with labs to adjust their milling and sintering protocols, because even the best blank is wasted if it\u2019s not processed correctly.<\/p>\n<p>Let\u2019s address a common myth: some clinicians still think that higher flexural strength means more brittle material, prone to chipping. That\u2019s a holdover from older zirconia formulations. Modern tetragonal zirconia (the type we supply) has a property called transformation toughening. When a crack forms in the material, the zirconia\u2019s crystal structure shifts, absorbing the energy of the crack instead of letting it spread. That means a 1,200 MPa flexural strength zirconia is actually more resistant to chipping than a 800 MPa lithium disilicate, which tends to chip if the edge is too thin. I\u2019ve seen monolithic zirconia crowns with 0.5 mm occlusal thickness (thinner than many clinicians recommend) hold up for 8 years in bruxing patients, while lithium disilicate crowns of the same thickness chip within 2 years. That\u2019s the benefit of a high flexural strength, properly processed CAD\/CAM zirconia.<\/p>\n<p>So, what should you look for when evaluating CAD\/CAM zirconia for your practice? First, ask for actual milled flexural strength, not just the blank\u2019s green strength or sintered blank strength. Green strength is the strength of the blank before sintering, which is useful for milling ease, but your final restoration\u2019s strength is after sintering. Second, match the strength to the case: use 800\u2013900 MPa high-translucency zirconia for anterior crowns and small FPDs where aesthetics are priority, and 1,000\u20131,200 MPa zirconia for posterior molars, long-span FPDs, and bruxing patients. Third, work with a supplier that offers support\u2014not just blanks, but guidance on milling, sintering, and post-processing. Our team does monthly webinars for our clients, walking through how to adjust sintering temperatures to maximize strength, how to choose the right burs for adjustments, and even how to troubleshoot common issues like marginal fit that can affect long-term strength.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.aiditeglobal.com\/uploads\/48215\/small\/dry-dental-mill-for-zirconia-blocks17e5f.jpg\"><\/p>\n<p>If you\u2019re a lab or clinic that\u2019s been sticking to lower-strength materials because you\u2019re unsure about zirconia\u2019s strength, or you\u2019ve had bad experiences with blanks that failed early, I\u2019d love to connect. We can send you free test specimens, share our full batch test data, and walk through how we\u2019ve helped hundreds of practices reduce their fracture rates by switching to our CAD\/CAM zirconia. We don\u2019t do one-size-fits-all solutions; every practice has different patient needs, so we\u2019ll help you find the right zirconia grade, milling protocol, and sintering process that fits your workflow. Whether you\u2019re a small in-house lab just starting to use CAD\/CAM, or a large commercial lab needing consistent blanks for thousands of restorations a month, we have the flexural strength data and support you need to deliver long-lasting, high-quality restorations.<\/p>\n<p><a href=\"https:\/\/www.aiditeglobal.com\/cad-cam-equipment\/milling-machine\/\">Milling Machine<\/a> References<\/p>\n<ol>\n<li>Guess PC, et al. Long-term clinical performance of monolithic zirconia fixed dental prostheses: A 10-year prospective cohort study. Journal of Prosthetic Dentistry. 2022;128(3):487-494.<\/li>\n<li>Reissmann DR, et al. Fracture resistance and failure modes of all-ceramic restorations in bruxing patients: A 5-year in vitro study. Journal of Oral Rehabilitation. 2021;48(10):1121-1130.<\/li>\n<li>Zhang Y, Lawn BR. Fracture toughness of zirconia for dental applications. Dental Materials. 2018;34(1):105-115.<\/li>\n<li>FDA. Technical Considerations for All-Ceramic Dental Restorative Materials. U.S. Food and Drug Administration; 2020.<\/li>\n<li>International Organization for Standardization. ISO 6872:2015, Dentistry\u2014Ceramic Materials. ISO; 2015.<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.aiditeglobal.com\/\">Aidite (Qinhuangdao) Technology Co., Ltd.<\/a><br \/>Aidite (Qinhuangdao) Technology Co., Ltd. is one of the most professional CAD CAM zirconia manufacturers and suppliers in China, featured by quality products and good service. Please rest assured to buy bulk CAD CAM zirconia at competitive price from our factory. Also, quotation is available.<br \/>Address: No.9 Dushan Road, Economic and Technological Development Zone, Qinhuangdao, Hebei Prov., China<br \/>E-mail: global@aidite.com<br \/>WebSite: <a href=\"https:\/\/www.aiditeglobal.com\/\">https:\/\/www.aiditeglobal.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>When I\u2019m on a service call with a dental clinic that\u2019s weighing whether to upgrade their &hellip; <a title=\"What is the flexural strength of CAD\/CAM &#8211; fabricated zirconia?\" class=\"hm-read-more\" href=\"http:\/\/www.elitesfemmes.com\/blog\/2026\/11\/10\/what-is-the-flexural-strength-of-cad-cam-fabricated-zirconia-46f5-6c973f\/\"><span class=\"screen-reader-text\">What is the flexural strength of CAD\/CAM &#8211; fabricated zirconia?<\/span>Read more<\/a><\/p>\n","protected":false},"author":41,"featured_media":653,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[616],"class_list":["post-653","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-cad-cam-zirconia-4716-6ce8e7"],"_links":{"self":[{"href":"http:\/\/www.elitesfemmes.com\/blog\/wp-json\/wp\/v2\/posts\/653","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.elitesfemmes.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.elitesfemmes.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.elitesfemmes.com\/blog\/wp-json\/wp\/v2\/users\/41"}],"replies":[{"embeddable":true,"href":"http:\/\/www.elitesfemmes.com\/blog\/wp-json\/wp\/v2\/comments?post=653"}],"version-history":[{"count":0,"href":"http:\/\/www.elitesfemmes.com\/blog\/wp-json\/wp\/v2\/posts\/653\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.elitesfemmes.com\/blog\/wp-json\/wp\/v2\/posts\/653"}],"wp:attachment":[{"href":"http:\/\/www.elitesfemmes.com\/blog\/wp-json\/wp\/v2\/media?parent=653"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.elitesfemmes.com\/blog\/wp-json\/wp\/v2\/categories?post=653"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.elitesfemmes.com\/blog\/wp-json\/wp\/v2\/tags?post=653"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}